Atmos Combi boiler for wood and pellets/heating oil DC32SP

£3,870.00

Prices incl. VAT
Shipping Cost: £ 250
Delivery: 10-21 days

Combined gasification boilers for wood or lignite and pellets or extra light fuel oil (ELFO)

The series of combined boilers ATMOS DC18SP(L), DC25SP(L), DC30SPX(L), DC32SP(L) enable to burn wood on the principle of generator gasification in combination with a burner for pellets (DCxxSP - code: H0048) or extra light fuel oil “ELFO“ (DCxxSPL). The boiler enables changing of fuels heating with wood and full automatic heating with pellets or extra light fuel oil (ELFO) depending on which burner is built into the boiler. If needed there is naturally the option to buy a boiler without a burner and select one later or to use a burner from the last boiler.

The boiler is constructed as a body of three chambers situated one above another. The two upper chambers serve for the gasification of the wood as you are familiar with from the classical gasification boilers that we produce as the standard. In the third lowest chamber is installed the required burner at the front and inlaid by ceramics to ensure the optimal quality of burning. Both the systems are separated by a water surface so that they do not interfere with each other and thanks to that the boiler achieves high efficacy when heating by the individual fuels. The combustion gases exhaustion is handled by one outlet and therefore only one chimney is needed.

The new combined boiler ATMOS C18SP and C25SP enable for ecological burning of lignite and wood as a spare fuel (firing up) on the principle of generator gasifying in combination with pellet burner - code: H0048.

The boiler is constructed as a body of three chambers situated one above another. The two upper chambers serve for the gasification of the lignite as you are familiar with from the classical gasification boilers  that we produce as the standard (CxxS(T)). In the third lowest chamber is installed ATMOS A25 pellet burner.

Kombi boiler C18SP - lignite/pellets

Advantages of ATMOS boilers

  • possible combination of the individual types of fuel - fuels changing without modifications in the boiler wood + pellets, wood + ELFO (DCxxSP(X)L), lignite + pellets (CxxSP)
  • possible substitution of the individual burners - at any time it is possible to choose a different fuel (pellets/heating oil)
  • high effectiveness in the individual fuels - for all practical purposes identical as in the special boilers for pellets or ELFO (up to 92.3% at the nominal output)
  • cheaper solution - adding the costs for the purchase of two boilers their installation and flue ducts (chimneys) we find that one boiler though more expensive is more economical
  • less built-up area compared to a greater number of boilers
  • one chimney and flue duct
  • ecological operation in all the versions of heating - boiler class 5 (ČSN EN 303-5), ECODESIGN 2015/1189 (DC25SP, DC30SPX, DC32SP, C18SP, C25SP)
  • boiler is equipped with feature of an automatic start-up of the pellet burner when all fuel (wood/lignite) is burnt out

​ ​

Regulation and control

The operation of the boiler is fully automatic to heat up water to required temperature with high efficiency and in a good quality of burning. All this ensure:

  • HONEYWELL draught regulator
  • boiler (regulating) thermostat - fan control thermostat
  • waste gas thermostat
  • pump thermostat
  • main switch and changeover switch for boiler operation

DCxxSP and CxxSP boilers and burners in version Model 2018/2019 are equipped with the function of automatic closing or opening of the air supply to the boiler/burner (using the actuator) when hearing with wood or pellets.
The boilers are equipped with an AGF2 flue gas sensor and a KTF20 boiler water temperature sensor for function of automatic burner start after the wood burns out. Than the boilers are equipped with two KTF20 sensors (TV and TS) for controlling the burner with two temperatures on the accumulation tank. The whole set is sold in the maximum range, for fully automatic mode and simple plug and play installation.

BELIMO actuator with the air regulating flap

Draught regulator FR 124

 

Control panel with standard regulation

Control panel composition:
Main switch, safety thermostat, thermometer, boiler (regulating) thermostat and waste gas thermostat.

Electro-mechanical regulation is an optimal solution for easy management of the operation of the boiler (exhaust fan).
The design of the panel with standard regulation is a basic design for all produced boilers.

Each boiler can be fitted with Equithermal regulation ATMOS ACD 01 for control of the heating system depending on the outdoor temperature, room temperature and time. This regulation is able to control boiler with a fan and many other features.

 

Exhaust fan and flue gas neck

Cooling loop of the boiler

Technical information

BOILER DRAWING FOR DCxxSP(X)

LEGEND FOR DCxxSP(X) BOILER DRAWING

1. Boiler body 20. Main switch with pilot light
2. Filling door (upper) for wood 21. Flue gas brake (only DC30SPX)
3. Ash-pan door (middle) 22. Draught regulator - Honeywell FR 124
4. Exhaust fan 23. Cooling loop protecting against overheating
5. Heatproof shaped piece - nozzle 24. Boiler (regulating) thermostat - fan control thermostat
6. Control panel 25. Door filling - Sibral
7. Safety thermostat (Caution – in overheat condition must be depressed) 26. Door sealing – cord 18 x 18
8. Regulating air flap 27. Heatproof shaped piece – half moon (door shield)
9. Heat proof shaped piece - extension of the spherical space - (pellets) 28. ATMOS A25 pellet burner - code: H0048
10. Heat proof shaped piece - spherical space - (pellets) 31. Heat proof shaped piece - spherical space - (wood)
11. Sealing cord - nozzles - 12 x 12 32. Heatproof shaped piece - back side of the spherical space - (wood)
12. Door for the pellet burner (bottom) 33. Pump thermostat
13. Ignition (firing up) valve 34. Fuse (6,3A) T6,3A/1500 - type H
14. Heatproof shaped piece - back side of the spherical space - (pelety) 35. Flue gas thermostat
15. Cleaning lid 36. Changeover switch (wood-0-pellets)
16. Primary air screen 37. End switch with button
17 Ignition (firing up) valve pulling rod 38. Capacitor of exhaust fan
18. Thermometer 39. Sibral gasket under the burner
19. Frame shield 40. Measurement point for the combustion gases - flue gas analyzer
41. BELIMO Actuator with the flap

BOILER DRAWING FOR C18SP

 

BOILER DRAWING FOR C25SP

LEGEND FOR C18SP BOILER DRAWING

1. Boiler body 27. Heatproof shaped piece – half moon (door shield) - lignite
2. Filling door (upper) for lignite 28. ATMOS A25 pellet burner - code: H0048
3. Ash-pan door (middle) 29. Door filling - Sibral - with opening for burner
4. Exhaust fan 30. Primary air inlet screen
5. Heatproof shaped piece – cube 31. Heat proof shaped piece - spherical space - (pellets)
6. Control panel 32. Heatproof shaped piece - back side of the spherical space - (pellets)
7. Safety thermostat (Caution – in overheat condition must be depressed) 33. Pump thermostat
8. Regulating air flap 34. Fuse (6,3A) T6,3A/1500 - type H
9. Fire-grate (segment) 35. Flue gas thermostat
10. Heat proof shaped piece - spherical space - (lignite) 36. Changeover switch (wood-0-pellets)
11. Fire-grate tube 37. End switch with button
12. Door for the pellet burner (bottom) 38. Capacitor of exhaust fan
13. Ignition (firing up) valve 39. Sibral gasket under the burner
14. Heatproof shaped piece - back side of the spherical space - (lignite) 40. Measurement point for the combustion gases - flue gas analyzer
15. Cleaning lid (upper, middle, bottom) 41. Secondary air regulation
16. Grating lever 42. Primary air regulation
17 Ignition (firing up) valve pulling rod 43. Door sealing – cord 18 x 18 - big door for burner
18. Thermometer 44. Combustion area screen - rear
19. Combustion area screen - front (frame shield) 45. Tube heat exchanger (only C25SP)
20. Main switch with pilot light 46. BELIMO actuator with the flap
22. Draught regulator - Honeywell FR 124 K gas outlet pipe
23. Cooling loop protecting against overheating L the boiler water outlet
24. Boiler (regulating) thermostat - fan control thermostat M the boiler water inlet
25. Door filling - Sibral N filling valve pipe sleeve
26. Door sealing – cord 18 x 18 P pipe sleeve for valve sensor controlling the cooling loop

 

Dimensions C18SP C25SP DC18SP DC25SP DC30SPX DC32SP
A 1665 1735 1665 1665 1665 1742
B 757 757 757 957 957 957
C 643 643 643 643 643 678
D 1375 1216 1375 1375 1375 1448
E 150/152 150/152 150/152 150/152 150/152 150/152
F 65 65 65 65 65 70
G 207 207 207 207 207 184
H 1436 1506 1436 1436 1436 1507
CH 212 212 212 212 212 212
I 212 212 212 212 212 212
J 6/4" 6/4" 6/4" 6/4" 6/4" 6/4"

 

TECHNICAL DATA C18SP C25SP DC18SP(L) DC25SP(L) DC30SPX(L) DC32SP(L)
Nominal output kW 20 25 20 27 30 35
Boiler output - pellets kW 4,5 - 15 4,5 - 18 4,5 - 15 6 - 20 6 - 20 6 - 20
Boiler output - oil (DCxxSPL) kW - - 15 - 20,5 15 - 30 15 - 30 15 - 30
Specified fuel for manual stocking (preffered DCxxSPL(SPXL)) Lignite (type NUT 1)
with a caloric power of 17 - 20 MJ/kg-1
Dry wood of 15 - 17 MJ.kg-1 caloric power,
12 % - 20 % water content and 80 - 150 mm diameter
Fuel for automatic stocking - pellets (preffered DCxxSP(SPX)) High quality pellets with diamter 6 - 8 mm with a caloric power of 15 - 18 MJ.kg-1
Fuel for automatic stocking - ELFO - - ELFO (extra light fuel oil) with a caloric power of 42 MJ.kg-1
Maximum wood length mm 330 330 330 530 530 530
Stocking chamber volume dm3 66 73 66 100 100 140
Boiler weight kg 461 486 435 531 537 596
Specified chimney draught Pa 20 23 20 23 23 24
Boiler water volume l 78 86 78 109 109 160
Max. operating water-pressure kPa 250 250 250 250 250 250
Connecting voltage V/Hz 230 / 50
Waste gas temperature at nominal output - lignite / wood °C 169 163 208 176 176 230
Waste gas temperature at nominal output - pellets °C 110 140 169 139 139 139
Boiler efficiency pellets / wood (lignite) / heating oil (SPL) % 92,5 / 88,9 / - 91,8 / 89,2 / - 92,5 / 90,1 / 89,6 91,2 / 89,9 / 90,3 91,2 / 89,9 / 90,3 91,2 / 88,9 / 90,3
Boiler class 5 5 5 5 5 5
Energy efficiency class A+ A+ A+ A+ A+ A+

Boilers designated for heating with wood in combination ELFO have the "L" suffix in their name (e.g. DC 18SPL).

Burners

Pellet burner - ATMOS A25

Pellet burner using for boilers DC18SP, DC25SP, DC30SPX, DC32SP, C18SP and C25SP

PELLET BURNER - ATMOS A25  (for models DCxxSP(X), CxxSP) - code: H0048

Specified fuel: good quality pellets with 6 – 8 mm diameter, 5 - 25 mm lenght and 16 - 19 MJ.kg-1 caloric power (white pellets).

The burner screen: used to display the current status of the burner and adjusting her functions.

Burner control: with an AC07X (AC07) electronic control unit that controls the operation of the external conveyor, two ignition spirals and the fan in accordance with requirements of the boiler and the heating system. The electronic system is rotected with the safety thermostat of the boiler, safety thermostat at the pellet supply to the burner, the fan speed transducer and the flame sensing photocell.The operation of the burner is indicated on the electronic control display.

Fuel feeding: with an external auger conveyor controlled from electronic regulation of burner.

Ignition of fuel: automatic assisted by two electric ignition spirals.

Basic functions of burner:

The possibility of using two spare outputs R and R2 for various applications
The possibility of the involvement of four different sensors TS, TV, TK a TSV
TS - sensor on the tank bottom
TV - sensor on the tank top
TK - boiler sensor or middle sensor on the tank
TSV - flue gas sensor or solar panel sensor

  • burner controlling it in accordance with two temperatures (sensors) on the buffer tank
  • control of boiler fan from burner with the help of the auxiliary output
  • control of boiler pump from burner with the help of the auxiliary output (R- reserve)
  • control of the solar system directly from the burner
  • automatic start of the burner after burning of wood for boilers DCxxSP(X) a C18SP

Burners are able to burn only good quality white pellets from soft wood without bark ø 6 - 8 mm, lenght 10 - 25 mm with heating power 16 - 19 MJ.kg-1. Burners are not able to burn pellets with high caking property in the burning chamber. In such case it is needed to clean the burning chamber in period one a day.

For these burners are appropriate conveyors:

  • Auger pellet conveyor for burner ATMOS A25 - DA1500 lenght1,5 m and diameter 75 mm
  • Auger pellet conveyor for burner ATMOS A25 - DA2000 lenght 2 m and diameter 75 mm
  • Auger pellet conveyor for burner ATMOS A25 - DA2500 lenght 2,5 m and diameter 75 mm
  • Auger pellet conveyor for burner ATMOS A25 - DA3000 lenght 3 m and diameter 75 mm
  • Auger pellet conveyor for burner ATMOS A25 - DA4000 lenght 4 m and diameter 75 mm

Burners extra light fuel oil (ELFO) for boilers DC18SPL, DC25SPL, DC30SPXL, DC32SPL,  C18SPL and C25SPL

When burning ELFO you can also use other manufacturers’ burners equipped with an air flap valve operated electrically or hydraulically (e.g. by an electric actuator) which is closed when the electric burner is off. (The reason is that “false air” must not be drawn into the combustion process during wood burning operation). These burners must be approved for operation in the particular country and must comply with all safety and combustion quality requirements effective in the particular country.

Instalation and connection

DCxxSP boiler with standard pellet tank 500 l

Boiler with compact pellet tank AZPD
and pnematic feading APS250S

 

RECOMMENDED INSTALLATION WITH LADDOMAT 22 AND BUFFER TANK

Doporučené zapojení

We recommend installing the boiler with Laddomat 22 or a thermo regulating valve with equalizing vessel 500 – 1, 000 litres. We also recommend installing the boiler with accumulating tanks of appropriate volume (e.g. 2.000 litres), which allow utilising electricity for heat accumulation or connecting solar panels. If necessary, the boiler can be connected into a system without accumulating tanks. This comes into account if you use fuel oil.