Accumulation tank with 1 maxi coil LEMET 500L
£1,325.00
Prices incl. VAT
Shipping Cost: £ 150
Delivery: 4-10 days
Buffer tanks with one Maxi type coil are characterized by a large coil surface area, which makes it possible to connect a heat pump (low temperature of the heating liquid) because it has a large heating surface.
Its insulation is made of polyurethane foam or a removable PU sponge. The buffer is placed in an aesthetic casing available in three colours: grey, red, dark blue.
Specification
| Symbol | 16.200B-1M | 16.300B-1M | 16.400B-1M | 16.500B-1M | 16.600B-1M | 16.800B-1M | 16.1000B-1M | ||||
| Nominal capacity | L | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | |||
| Tank maximum working temp. and pressure | 95 °C / 3 Bar | ||||||||||
| Coil maximum working temp. and pressure | 95 °C / 6 Bar | ||||||||||
| Insulation | PUR | Removable | |||||||||
| Weight | kg | 103 | 145 | 186 | 199 | 222 | 276 | 300 | |||
| Lower coil heat | Surface | m2 | 1.9 | 3.2 | 4.5 | 4.8 | 5.1 | 6.0 | 6.5 | ||
| Capacity | L | 9.4 | 15.8 | 23.5 | 25 | 26.2 | 31 | 33.4 | |||
| KP | Connection stub pipe | G 6/4" W/F |
| T | Input for Thermometer | G 3/4" W/F |
| OZ | Tank air went | G 6/4" W/F |
| CT | Pipe for temperature sensor | |
| ZWD | Lower coil inlet | G 1" W/F |
| PWD | Lower coil outlet | G 1” W/F |
Size Tank
| A | B | C | D | E | F | G | H | I | J | K | |
| 16.200B-1M | 1250 | 1010 | 600 | 500 | 740 | 465 | 190 | 190 | 465 | 740 | 1010 |
| 16.300B-1M | 1560 | 1270 | 650 | 550 | 930 | 590 | 250 | 250 | 590 | 930 | 1270 |
| 16.400B-1M | 1700 | 1400 | 650 | 550 | 1020 | 640 | 260 | 260 | 640 | 1020 | 1400 |
| 16.500B-1M | 1770 | 1495 | 810 | 650 | 1075 | 655 | 240 | 240 | 655 | 1075 | 1495 |
| 16.600B-1M | 2070 | 1795 | 810 | 650 | 1280 | 760 | 240 | 240 | 760 | 1280 | 1795 |
| 16.800B-1M | 1890 | 1589 | 960 | 800 | 1156 | 723 | 290 | 290 | 723 | 1156 | 1589 |
| 16.1000B-1M | 2180 | 1750 | 960 | 800 | 1255 | 760 | 260 | 260 | 760 | 1240 | 1750 |
Product Specification:
| Boiler water capacity | 500 l |
| Amount of coils | 1 item |
| Weight (without isolation) | 199 kg |
| Maximum boiler water temperature | 95 °C |
| Maximum pressure for boiler water tank | 0.3 MPa |
| Coil size (bottom) | 4.8 m² |
| Maximum temp. for solar / central heating coil | 95 °C |
| Maximum pressure for bottom coil | 0.6 MPa |
| Height | 1770 mm |
| Diameter (without isolation) | 650 mm |
| Diameter (with isolation) | 810 mm |
| External Enclosure | skay |
Additional information
| Weight | 199 kg |
|---|---|
| Dimensions | 177 cm |